🛠️ This is a sandbox environment
Published May 14, 2002 | Version v1

Field quality analysis to monitor the industrial series production of the dipole magnets for the Large Hadron Collider

Authors/Creators

  • 1. Turin Polytechnic
  • 2. ASP Turin
  • 3. ROR icon European Organization for Nuclear Research

Description

In superconducting accelerator magnets, the field quality is mainly determined by conductor position inside the coil. For the LHC, the dipolar field homogeneity must be assured up to 10-5 of the main field component, imposing strict manufacturing tolerances. Magnetic measurements at room temperature provide a fast and economical way to find out assembly errors or the use of faulty components. In order to compute control bounds for the industrial series production, the magnetic measurements performed at room temperature on 27 pre-series collared coils have been statistically analyzed in this work. An automatic tool has been implemented to single out anomalous values of the magnetic field in the measurements. Such cases have been analyzed using a magnetostatic code to work out errors in the manufacturing process and the possible cures.
To loan this literature, see Library holdings in the CERN Library Catalogue website.

Files

thesis-2003-002.pdf

Files (2.4 MB)

Name Size Download all
md5:4eaa645b1bb07dcd595f69440c2ccff7
2.4 MB Preview Download